Common Description
Outfitted using the zero leak bidirectional checking sole-noid valves, this energy unit is made for your operation of two independent circuits. Which are respectively for that main and subordinate platforms of the double scissors lift. Two cut-off valves are used for lowering the machine manually in situation of electrical power reduction. If a lot more independent circuits are expected to your application please contact us for availability.
Remark: 1. Please consult our income engineer for your unique pump displacement, motor energy or tank capacity.
two. CSA or UL certified motors are available on request.
Special Notes
1. The AC motor is of S3 duty cycle, which can only do the job intermittently and repeatedly, i.e., 1minute on and 9 minutes off.
2. Clean every one of the hydraulic elements concerned before installation of the energy unit.
3. Viscosity on the oil shoud be 15~46 cst,and the oil need to be clean and no cost of impurities,N46 hydraulic oil is advised.
four. The power unit should be mounted vertically.
5. Check the oil level inside the tank following the preliminary operating in the energy unit.
six. Oil altering is required right after the first 100 operation hrs,afterwards when each and every 3000 hours.
Energy UNITS FOR DOUBLE-SCISSORS LIFT
Tags: